Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Molecules ; 9(3): 117-24, 2004 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-18007416

RESUMO

The mono-epoxidation of geraniol by dimethyldioxirane was carried out in various solvents. In all cases, the product ratios for the 2,3 and 6,7 mono-epoxides were in agreement with literature values. Kinetic studies were carried out at 23 degrees C in the following dried solvent systems: acetone (k(2) = 1.49 M(-1)s(-1)), carbon tetrachloride/acetone(9/1, k(2)=2.19 M(-1)s(-1)), and methanol/acetone (9/1, k(2) = 17 M(-1)s(-1)). Individual k(2) values were calculated for epoxidation of the 2,3 and 6,7 positions in geraniol. The non-conjugated diene system was modeled employing two simple independent alkenes:2-methyl-2-pentene and 3-methyl-2-buten-1-ol by determining the respective k(2) values for epoxidation in various solvents. The kinetic results for each independent alkene showed that the relative reactivity of the two epoxidation sites in geraniol as a function of solvent was not simply a summation of the independent alkene systems.


Assuntos
Antioxidantes/química , Compostos de Epóxi/química , Terpenos/química , Monoterpenos Acíclicos , Cinética , Solventes/química
2.
J Forensic Sci ; 46(3): 661-76, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11373005

RESUMO

With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised > or = 5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType PM+DQA1, and/or D1S80) were amplified using AmpFlSTR Profiler Plus and COfiler and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects or victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.


Assuntos
Impressões Digitais de DNA/métodos , Eletroforese Capilar , Reação em Cadeia da Polimerase/métodos , Medicina Legal/métodos , Amplificação de Genes , Humanos , Reprodutibilidade dos Testes , Software , Espectrometria de Fluorescência , Sequências de Repetição em Tandem
3.
J Forensic Sci ; 46(3): 647-60, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11373004

RESUMO

The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.


Assuntos
Impressões Digitais de DNA/métodos , Reação em Cadeia da Polimerase/métodos , Sequências de Repetição em Tandem/genética , Medicina Legal/métodos , Amplificação de Genes , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes , Espectrometria de Fluorescência
4.
J Forensic Sci ; 44(6): 1277-86, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10582369

RESUMO

Allele distributions for 13 tetrameric short tandem repeat (STR) loci, CSF1PO, FGA, TH01, TPOX, VWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11, were determined in African American, United States Caucasian, Hispanic, Bahamian, Jamaican, and Trinidadian sample populations. There was little evidence for departures from Hardy-Weinberg expectations (HWE) in any of the populations. Based on the exact test, the loci that departed significantly from HWE are: D21S11 (p = 0.010, Bahamians); CSF1PO (p = 0.014, Trinidadians); TPOX (p = 0.011, Jamaicans and p = 0.035, U.S. Caucasians); and D16S539 (p = 0.043, Bahamians). After employing the Bonferroni correction for the number of loci analyzed (i.e., 13 loci per database), these observations are not likely to be significant. There is little evidence for association of alleles between the loci in these databases. The allelic frequency data are similar to other comparable data within the same major population group.


Assuntos
Impressões Digitais de DNA , Etnicidade/genética , Genética Populacional , Sequências de Repetição em Tandem/genética , Adulto , Alelos , Bahamas/epidemiologia , População Negra/genética , Bases de Dados Factuais , Medicina Legal/métodos , Hispânico ou Latino/genética , Humanos , Jamaica/epidemiologia , Trinidad e Tobago/epidemiologia , Estados Unidos/epidemiologia , População Branca/genética
5.
J Forensic Sci ; 44(6): 1277-86, Nov. 1999.
Artigo em Inglês | MedCarib | ID: med-757

RESUMO

Allele distributions for 13 tetrameric short tandem repeat (STR) loci, CSF1PO, FGA, TH01, TPOX, VWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11, were determined in African-American, United States Caucasian, Hispanic, Bahamian, Jamaican, and Trinidadian sample populations. There was little evidence for departure from Hardy-Weinberg expectations (HWE) in any of the populations. Based on the exact test, the loci that departed significantly from HWE are: D21S11 (p=0.010, Bahamians); CSF1PO (p=0.014, Trinidadians); TPOX (p=0.011, Jamaicans and p= 0.035, U.S. Caucasians); and D16S539 (p=0.043, Bahamians). After employing the Bonferroni correction for the number of loci analyzed (i.e., 13 loci per database), these observations are not likely to be significant. There is little evidence for association of alleles between the loci in these databases. The allelic frequency data are similar to other comparable data within the same major population group. (AU)


Assuntos
Adulto , Humanos , Impressões Digitais de DNA , Etnicidade/genética , Genética Populacional , Sequências de Repetição em Tandem/genética , Alelos , Bahamas/epidemiologia , /genética , Bases de Dados Factuais , Medicina Legal/métodos , Hispânico ou Latino/genética , Jamaica/epidemiologia , /genética , Trinidad e Tobago/epidemiologia , Estados Unidos/epidemiologia
6.
J Forensic Sci ; 38(5): 1028-36, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8228874

RESUMO

The apparent stability of DNA in forensic samples has permitted the successful application of several techniques such as polymerase chain reaction (PCR)-based and restriction fragment length polymorphisms (RFLP) analysis to forensic cases. PCR-based typing of the HLA-DQ alpha region in forensic casework has been shown to be a valid and reliable technique. This inherent stability of DNA in forensic evidence has led us to address the question of whether DNA could successfully withstand certain evidence processes such as latent fingerprint and electrostatic detection apparatus (ESDA) processing and still yield a sufficient quantity and quality of DNA for PCR HLA DQ alpha typing. Through testing done with biological material on simulated and casework envelope, stamp, and cigarette butt type evidence, it was determined that samples could be processed for specific latent fingerprint and ESDA examinations and still yield sufficient DNA for conclusive HLA DQ alpha typing results.


Assuntos
Impressões Digitais de DNA , Dermatoglifia , Amplificação de Genes , Genes MHC da Classe II , Antígenos HLA-DQ/genética , Humanos , Reação em Cadeia da Polimerase
7.
J Forensic Sci ; 38(2): 239-49, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8095967

RESUMO

The polymerase chain reaction (PCR) was used to amplify the HLA DQ alpha gene using DNA recovered from evidentiary samples. Amplified HLA DQ alpha DNA was then typed using sequence-specific oligonucleotide probes. Slight modifications of previously published DNA extraction methods improved typing success of bloodstains and semen-containing material. Evidentiary samples, consisting of 206 known bloodstains, 26 questioned bloodstains, and 123 questioned semen-containing evidentiary materials were analyzed from 96 cases previously analyzed by restriction fragment length polymorphism (RFLP) typing in the FBI Laboratory. Of the known bloodstains, 98.5% yielded DQ alpha typing results. Of the questioned samples, 102 of 149 (24/26 bloodstains and 78/123 semen-containing materials), or 68%, produced typing results. Of the 78 cases that were RFLP inclusions, 59 yielded interpretable DQ alpha results and these were all inclusions. The remaining 19 cases could not be interpreted for DQ alpha. Of the 18 RFLP exclusions, eleven were DQ alpha exclusions, four were DQ alpha inclusions, and three could not be interpreted for DQ alpha. It is expected that because of the difference in discrimination potential of the two methods, some RFLP exclusions would be DQ alpha inclusions. Some samples that failed to produce typing results may have had insufficient DNA for analysis. Employment of a human DNA quantification method in DQ alpha casework would allow the user to more consistently use sufficient quantities of DNA for amplification. It also could provide a guide for determining if an inhibitor of PCR is present, thus suggesting the use of a procedure to improve amplification. This study provides support that the HLA DQ alpha typing procedure is valid for typing forensic samples.


Assuntos
Medicina Legal , Antígenos HLA-DQ/genética , Reação em Cadeia da Polimerase , Amplificação de Genes , Antígenos HLA-DQ/análise , Cadeias alfa de HLA-DQ , Teste de Histocompatibilidade , Humanos , Immunoblotting , Polimorfismo de Fragmento de Restrição
8.
J Forensic Sci ; 36(5): 1284-98, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1683360

RESUMO

Deoxyribonucleic acid (DNA) restriction fragment length polymorphism (RFLP) profile results were obtained from bloodstains and other body fluid stains subjected to mixture with other body fluids, environmental insults (sunlight and temperature), different substrates (cotton, nylon, blue denim, glass, aluminum, and wood), and contaminants (gasoline, bleach, sodium hydroxide, soil, motor oil, detergent, phosphate salt, glacial acetic acid, and microorganisms). Of the samples that produced profile results, all had profiles that were consistent with those of untreated control samples.


Assuntos
Manchas de Sangue , Líquidos Corporais/química , DNA/sangue , Polimorfismo de Fragmento de Restrição , DNA/análise , DNA/efeitos da radiação , Humanos , Reprodutibilidade dos Testes , Luz Solar , Temperatura , Fatores de Tempo
9.
J Med Chem ; 28(7): 940-4, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-4009616

RESUMO

A series of 6-chloro-2-substituted-9-[[3-(dimethylamino)propyl]amino]acridines has been prepared. The binding affinities and the unwinding angles for the acridine derivatives, relative to ethidium, were determined from viscometric titrations with ccs-DNA. The binding affinities were the same, within experimental error, ca. 2.0 X 10(-5). Similarly, with the exception of 11, the unwinding angles were close to 17 degrees. For 11 the unwinding angle (12 degrees) was smaller than the other derivatives. The general insensitivity of the apparent binding constants to substituent effects is attributable to a masking effect of the formal charge on the ring. The smaller unwinding angle for 11 is believed to arise from its relative dissymmetry, resulting in a "wedge" effect upon intercalation.


Assuntos
Aminoacridinas/metabolismo , DNA/metabolismo , Aminoacridinas/síntese química , Animais , Bovinos , Fenômenos Químicos , Química , DNA Circular/metabolismo , DNA Super-Helicoidal/metabolismo , Etídio/metabolismo , Concentração de Íons de Hidrogênio , Espectrofotometria , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...